Feasibility of gel-like radiopaque embolic material using gelatin sponge and contrast agent for tract embolization after percutaneous treatment.

Bibliographic Details
Title: Feasibility of gel-like radiopaque embolic material using gelatin sponge and contrast agent for tract embolization after percutaneous treatment.
Authors: Nota, Takehito1 (AUTHOR), Kageyama, Ken1 (AUTHOR) kageyama@omu.ac.jp, Yamamoto, Akira1 (AUTHOR), Jogo, Atsushi1 (AUTHOR), Sohgawa, Etsuji1 (AUTHOR), Yonezawa, Hiroki1 (AUTHOR), Murai, Kazuki1 (AUTHOR), Ogawa, Satoyuki1 (AUTHOR), Miki, Yukio1 (AUTHOR)
Superior Title: PLoS ONE. 2/3/2023, Vol. 17 Issue 2, p1-13. 13p.
Subject Terms: *CONTRAST media, *GELATIN, *NEURAL stimulation, *ANIMAL experimentation, *VISCOSITY
Abstract: Objectives: Tract embolization has been performed to prevent bleeding after trans-organ puncture. This study evaluated clinical outcomes of tract embolization using a gel-like radiopaque material comprising two sheets of gelatin sponge and 3 mL of contrast agent, and experimentally confirmed its viscosity and hemostatic efficacy. Methods: Three study phases were planned. In a clinical setting, 57 consecutive patients who underwent tract embolization after transhepatic puncture were retrospectively analyzed. Clinical success was evaluated as absence of bleeding complications for 30 days after the procedure. In a basic experiment, viscosity of the material was analyzed. In an animal experiment, rabbit kidney puncture site was embolized via a 7-Fr sheath using this material, coils, or N-butyl-2-cyanoacrylate glue or received no embolization while removing the sheath. Amounts of tract bleeding were measured for 1 min and compared between groups. Results: Embolization was successfully completed in all clinical cases. No postoperative bleeding requiring intervention was encountered. The basic experiment revealed the material was highly viscous. In the animal experiment, mean weights of bleeding in the control, gel-like embolic material, coil, and N-butyl-2-cyanoacrylate glue groups were 1.04±0.32 g, 0.080±0.056 g, 0.20±0.17 g and 0.11±0.10 g, respectively. No significant differences were seen among embolization groups, while the control group showed significantly more bleeding than any embolization group. Conclusion: Tract embolization with this gel-like radiopaque embolic material appears safe and feasible. Advances in knowledge: Tract embolization using this embolic material with two sheets of gelatin sponge and 3 mL of contrast agent offers a safe, feasible, and economical procedure after trans-organ puncture, because the material offers the following characteristics: visibility under X-ray; viscosity facilitating retention in the tract; ability to allow repeated puncture via the same route; and low cost. [ABSTRACT FROM AUTHOR]
Copyright of PLoS ONE is the property of Public Library of Science and its content may not be copied or emailed to multiple sites or posted to a listserv without the copyright holder's express written permission. However, users may print, download, or email articles for individual use. This abstract may be abridged. No warranty is given about the accuracy of the copy. Users should refer to the original published version of the material for the full abstract. (Copyright applies to all Abstracts.)
Database: Academic Search Premier
Full text is not displayed to guests.
Description
Description not available.